SFRreg: Why Wide-FOV and Ultra-Wide Systems Use Multiple Registration Targets Instead of One Large Chart
A single flat chart can’t be the right size, distance, and focus across a wide field of view — corners end up defocused and foreshortened. This article explains why ultra-wide, fisheye, automotive, and endoscope MTF testing uses multiple SFRreg registration targets instead: each is placed and angled for its field position, covering center and corners (plus sagittal/tangential MTF and lateral CA) in a single capture.
Optical Density vs Contrast Ratio: What 10:1 and 4:1 Really Mean

Optical density and contrast ratio describe the same thing, linked by one equation: contrast ratio = 10^(ΔOD). This article shows how to convert between them, why 10:1 = OD 1.0 and 4:1 ≈ OD 0.6, and why opaque chrome (OD 3 ≈ 1000:1) can never be a low-contrast target.
Why ISO 12233 Slanted-Edge MTF Requires a Low-Contrast Target (4:1 vs 10:1 vs High Contrast)

The slanted-edge method only gives a true MTF when the camera responds linearly. A high-contrast black-to-white edge clips and triggers sharpening, inflating the result. This article explains why ISO 12233’s low-contrast edge — about 4:1 — keeps the edge in the linear range, and compares 4:1, 10:1, and high-contrast targets.
AprilGrid Calibration Targets: Coded AprilTag Grids for Kalibr Camera-IMU and Multi-Camera Calibration

An AprilGrid is a grid of individually coded AprilTags used by the Kalibr toolbox for multi-camera and camera-IMU calibration. Unique tag IDs let calibration succeed from partial views and remove the pose-flip ambiguity that affects symmetric checkerboards and circle grids. What it is, why Kalibr recommends it, the tag parameters that matter, how it differs from ChArUco, and how substrate sets the accuracy ceiling.
How to Evaluate Checkerboard Calibration Target Accuracy: 4 Numbers That Matter

A supplier’s inspection report is the only way to trust a calibration target you can’t easily measure yourself, yet most reports mix real fabrication error with the mounting offset and rotation from the measurement stage. The two kinds of accuracy (position vs spacing), the four numbers that matter (pass rate, maximum radial residual, standard deviation, 95th percentile), why Kabsch rigid-body alignment is non-negotiable, a worked example, and five red flags when reading a supplier’s report.
How Calibration Targets Are Made: Photolithography, Chrome-on-Glass, and Acceptance Inspection

A calibration is only as accurate as the target it is derived from, so how a target is made is the floor the whole measurement sits on. Why photolithographic chrome-on-glass beats printing (sub-micron versus 50–300 µm edges), the five quality parameters that define a professional target, how chrome-on-glass is produced step by step, how substrate and chrome are chosen, and how CalibVision’s fabless model qualifies partners and inspects every finished part before shipment.
Dot Grid vs. Checkerboard: Which Calibration Target Is Right for Your Machine Vision System?

If you’re setting up a machine vision system — whether it’s for factory inspection, robotics, or 3D measurement — you’ve probably run into one question pretty quickly: Should I use a dot grid or a checkerboard calibration target? It sounds like a simple choice. But the wrong target can cost you hours of rework, inconsistent […]
How to Choose and Customize a ChArUco Calibration Board for Professional Camera Calibration

Discover ChArUco calibration boards for professional camera calibration. Custom-made glass, ceramic, and film targets with ±0.3 µm precision.